What this page is. A placement-times-estimated-dissipation attention map: where the dissipating parts sit, where they cluster, and which heat-sensitive parts sit near them. It is not a thermal simulation: there is no airflow, no ambient, no heatsink or heat-spreader model and no measured current. The spread view is relative (normalised to its own maximum) and must never be read as a temperature.
Placement is the real board: every part's position, rotation, side and body from the layout database, validated against the copper (100 % of pins on their pads, 100 % of pin nets equal to the schematic netlist) and cross-checked against two further placement sources (1044 of 1044 parts agree within 0.01 mm). The SSD card zone is the M.2 2280 outline between the connector and its standoff.
Dissipation model: a power tree, not a list. Each regulator's load is everything its output feeds on this board (parts, modules and the input current of the regulators below it), followed from the schematic netlist; the tree is evaluated from the leaves up to the 12 V input, so the 12 V input power always equals the sum of every part's dissipation (shown above the boards). Inputs: the CPU power limit P, the LPCAMM2 module power, the SSD power, peripheral activity (datasheet maximum or typical) and the fitted assembly options.
Thermal resistances in the data table are printed only where the vendor's public datasheet publishes them, with the document named. theta-JC is junction to case top unless marked; theta-JB is junction to board; Psi values are characterisation parameters, not resistances, and are given in the notes. An empty cell means the vendor does not publish the value.
Conduction. The in-plane sheet conductance of the real 8-layer stackup, kt = sum over layers of kCu x ti x coveragei + kFR4 x tdielectric, with copper weights from the layout database and the copper coverage of each layer from a 0.05 mm union raster of every copper feature. The source map is spread with the Green's function of a thin plate losing heat from both faces, K0(r / lambda), lambda = sqrt(kt / h); h is a normalisation constant, not a cooling model. Outer layers are credited with 25 um of plating (assumption).
| Layer | oz | t (um) | Coverage | kCu x t x coverage (W/K) |
|---|---|---|---|---|
| signal 1 | 0.330 | 36.5 | 0.3397 | 0.00483 |
| plane 2 | 0.330 | 11.5 | 0.9128 | 0.00409 |
| signal 3 | 0.500 | 17.4 | 0.1537 | 0.00104 |
| signal 4 | 0.500 | 17.4 | 0.5364 | 0.00364 |
| plane 5 | 0.500 | 17.4 | 0.8365 | 0.00568 |
| signal 6 | 0.500 | 17.4 | 0.1485 | 0.00101 |
| plane 7 | 0.330 | 11.5 | 0.9062 | 0.00406 |
| signal 8 | 0.330 | 36.5 | 0.4197 | 0.00597 |
| FR4, all dielectrics | - | 1742.4 | - | 0.00052 |
kt = 0.03034 W/K (copper) + 0.00052 W/K (FR4: 0.30 W/mK x 1742.4 um) = 0.03086 W/K; h = 20 W/m2K; lambda = 39.3 mm.
Spread view in this page. The spread is linear in the part powers, so each dissipating part's response to 1 W is precomputed on a 0.25 mm grid, averaged to 1 mm cells, and summed with the powers of the selected state. Parts below 5 mW in every state are listed but not spread. Attention = the spread value at a part's centre divided by the maximum of the same view.
Limits.